40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature

CFR > Title 40 > Chapter I > Part 53 > § 53.55. Test for effect of variations in power line voltage and ambient temperature


Current as of: July 2009

(a) Overview. (1) This test procedure is a combined procedure to test various performance parameters under variations in power line voltage and ambient temperature. Tests shall be conducted in a temperature-controlled environment over four 6-hour time periods during which reference temperature and flow rate measurements shall be made at intervals not to exceed 5 minutes. Specific parameters to be evaluated at line voltages of 105 and 125 volts and temperatures of -20 [deg]C and +40 [deg]C are as follows:

(i) Sample flow rate.

(ii) Flow rate regulation.

(iii) Flow rate measurement accuracy.

(iv) Coefficient of variability measurement accuracy.

(v) Ambient air temperature measurement accuracy.

(vi) Proper operation of the sampler when exposed to power line voltage and ambient temperature extremes.

(2) The performance parameters tested under this procedure, the corresponding minimum performance specifications, and the applicable test conditions are summarized in table E-1 of this subpart. Each performance parameter tested, as described or determined in the test procedure, must meet or exceed the associated performance specification given. The candidate sampler must meet all specifications for the associated PM2.5 or PM10-2.5 method (as applicable) to pass this test procedure.

(b) Technical definition. Sample flow rate means the quantitative volumetric flow rate of the air stream caused by the sampler to enter the sampler inlet and pass through the sample filter, measured in actual volume units at the temperature and pressure of the air as it enters the inlet.

(c) Required test equipment. (1) Environmental chamber or other temperature-controlled environment or environments, capable of obtaining and maintaining temperatures at -20 [deg]C and =40 [deg]C as required for the test with an accuracy of 2 [deg]C. The test environment(s) must be capable of maintaining these temperatures within the specified limits continuously with the additional heat load of the operating test sampler in the environment. Henceforth, where the test procedures specify a test or environmental ``chamber,'' an alternative temperature-controlled environmental area or areas may be substituted, provided the required test temperatures and all other test requirements are met.

(2) Variable voltage AC power transformer, range 100 Vac to 130 Vac, with sufficient current capacity to operate the test sampler continuously under the test conditions.

(3) Flow rate meter, suitable for measuring and recording the actual volumetric sample flow rate at the sampler downtube, with a minimum range of 10 to 25 actual L/min, 2 percent certified, NIST-traceable accuracy. Optional capability for continuous (analog) recording capability or digital recording at intervals not to exceed 5 minutes is recommended. While a flow meter which provides a direct indication of volumetric flow rate is preferred for this test, an alternative certified flow measurement device may be used as long as appropriate volumetric flow rate corrections are made based on measurements of actual ambient temperature and pressure conditions.

(4) Ambient air temperature recorder, range -30 [deg]C to =50 [deg]C, with a resolution of 0.1 [deg]C and certified accurate to within 0.5 [deg]C. Ambient air temperature measurements must be made using continuous (analog) recording capability or digital recording at intervals not to exceed 5 minutes.

(5) Barometer, range 600 mm Hg to 800 mm Hg, certified accurate to 2 mm Hg. If the certified flow rate meter does not provide direct volumetric flow rate readings, ambient pressure measurements must be made using continuous (analog) recording capability or digital recording at intervals not to exceed 5 minutes.

(6) Flow measurement adaptor (40 CFR part 50, appendix L, figure L-30) or equivalent adaptor to facilitate measurement of sampler flow rate at the sampler downtube.

(7) Means for creating an additional pressure drop of 55 mm Hg in the sampler to simulate a heavily loaded filter, such as an orifice or flow restrictive plate installed in the filter holder or a valve or other flow restrictor temporarily installed in the flow path near the filter.

(8) AC RMS voltmeter, accurate to 1.0 volt.

(9) Teflon sample filter, as specified in section 6 of 40 CFR part 50, appendix L (if required).

(d) Calibration of test measurement instruments. Submit documentation showing evidence of appropriately recent calibration, certification of calibration accuracy, and NIST-traceability (if required) of all measurement instruments used in the tests. The accuracy of flow rate meters shall be verified at the highest and lowest pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within 3 percent of 16.7 L/min within 7 days prior to use for this test. Where an instrument's measurements are to be recorded with an analog recording device, the accuracy of the entire instrument-recorder system shall be calibrated or verified.

(e) Test setup. (1) Setup of the sampler shall be performed as required in this paragraph (e) and otherwise as described in the sampler's operation or instruction manual referred to in Sec. 53.4(b)(3). The sampler shall be installed upright and set up in the temperature-controlled chamber in its normal configuration for collecting PM samples. A sample filter and (or) the device for creating an additional 55 mm Hg pressure drop shall be installed for the duration of these tests. The sampler's ambient temperature, ambient pressure, and flow measurement systems shall all be calibrated per the sampler's operating manual within 7 days prior to this test.

(2) The inlet of the candidate sampler shall be removed and the flow measurement adaptor installed on the sampler's downtube. A leak check as described in the sampler's operation or instruction manual shall be conducted and must be properly passed before other tests are carried out.

(3) The inlet of the flow measurement adaptor shall be connected to the outlet of the flow rate meter.

(4) The ambient air temperature recorder shall be installed in the test chamber such that it will accurately measure the temperature of the air in the vicinity of the candidate sampler without being unduly affected by the chamber's air temperature control system.

(f) Procedure. (1) Set up the sampler as specified in paragraph (e) of this section and otherwise prepare the sampler for normal sample collection operation as directed in the sampler's operation or instruction manual.

(2) The test shall consist of four test runs, one at each of the following conditions of chamber temperature and electrical power line voltage (respectively):

(i) -20 [deg]C 2 [deg]C and 105 1 Vac.

(ii) -20 [deg]C 2 [deg]C and 125 1 Vac.

(iii) =40 [deg]C 2 [deg]C and 105 1 Vac.

(iv) =40 [deg]C 2 [deg]C and 125 1 Vac.

(3) For each of the four test runs, set the selected chamber temperature and power line voltage for the test run. Upon achieving each temperature setpoint in the chamber, the candidate sampler and flow meter shall be thermally equilibrated for a period of at least 2 hours prior to the test run. Following the thermal conditioning time, set the sampler to automatically start a 6-hour sample collection period at a convenient time.

(4) During each 6-hour test period:

(i) Measure and record the sample flow rate with the flow rate meter at intervals not to exceed 5 minutes. If ambient temperature and pressure corrections are necessary to calculate volumetric flow rate, ambient temperature and pressure shall be measured at the same frequency as that of the certified flow rate measurements. Note and record the actual start and stop times for the 6-hour flow rate test period.

(ii) Determine and record the ambient (chamber) temperature indicated by the sampler and the corresponding ambient (chamber) temperature measured by the ambient temperature recorder specified in paragraph (c)(4) of this section at intervals not to exceed 5 minutes.

(iii) Measure the power line voltage to the sampler at intervals not greater than 1 hour.

(5) At the end of each test run, terminate the sample period (if not automatically terminated by the sampler) and download all archived instrument data from the test sampler.

(g) Test results. For each of the four test runs, examine the chamber temperature measurements and the power line voltage measurements. Verify that the temperature and line voltage met the requirements specified in paragraph (f) of this section at all times during the test run. If not, the test run is not valid and must be repeated. Determine the test results as follows:

(1) Mean sample flow rate. (i) From the certified measurements (Qref) of the test sampler flow rate, tabulate each flow rate measurement in units of L/min. If ambient temperature and pressure corrections are necessary to calculate volumetric flow rate, each measured flow rate shall be corrected using its corresponding temperature and pressure measurement values. Calculate the mean flow rate for each sample period (Qref,ave) as follows:















Equation 11[GRAPHIC] [TIFF OMITTED] TR18JY97.073where:n equals the number of discrete certified flow rate measurements over each 6-hour test period.

(ii)(A) Calculate the percent difference between this mean flow rate value and the design value of 16.67 L/min, as follows:















Equation 12[GRAPHIC] [TIFF OMITTED] TR18JY97.074

(B) To successfully pass this test, the percent difference calculated in Equation 12 of this paragraph (g)(1)(ii) must be within 5 percent for each test run.

(2) Sample flow rate regulation. (i) From the certified measurements of the test sampler flow rate, calculate the sample coefficient of variation of the discrete measurements as follows:















Equation 13[GRAPHIC] [TIFF OMITTED] TR18JY97.075

(ii) To successfully pass this test, the calculated coefficient of variation for the certified flow rates must not exceed 2 percent.

(3) Flow rate measurement accuracy. (i) Using the mean volumetric flow rate reported by the candidate test sampler at the completion of each 6-hour test (Qind,ave), determine the accuracy of the reported mean flow rate as:















Equation 14[GRAPHIC] [TIFF OMITTED] TR18JY97.076

(ii) To successfully pass this test, the percent difference calculated in Equation 14 of this paragraph (g)(3) shall not exceed 2 percent for each test run.

(4) Flow rate coefficient of variation measurement accuracy. (i) Using the flow rate coefficient of variation indicated by the candidate test sampler (%CVind), determine the accuracy of the reported coefficient of variation as:















Equation 15[GRAPHIC] [TIFF OMITTED] TR18JY97.077

(ii) To successfully pass this test, the absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run.

(5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the difference between the mean ambient air temperature indicated by the test sampler and the mean ambient (chamber) air temperature measured with the ambient air temperature recorder as:[GRAPHIC] [TIFF OMITTED] TR17OC06.037Where:Tind,ave = The mean ambient air temperature indicated by the test sampler, [deg]C; and Tref,ave = The mean ambient air temperature measured by the reference temperature instrument, [deg]C.

(ii) The calculated temperature difference must be less than 2 [deg]C for each test run.

(6) Sampler functionality. To pass the sampler functionality test, the following two conditions must both be met for each test run:

(i) The sampler must not shutdown during any portion of the 6-hour test.

(ii) An inspection of the downloaded data from the test sampler verifies that all the data are consistent with normal operation of the sampler.

[62 FR 38799, July 18, 1997, as amended at 71 FR 61291, Oct. 17, 2006]
previous sectionPart 53 Table of Contentsnext section
Previous sectionPart 53 Table of ContentsNext section

________________________________________________________________________

U.S. Code Provisions: Air Pollution

U.S. Code > Title 42 > Chapter 15B - Air Pollution Control
U.S. Code > Title 42 > Chapter 85 - Air Pollution Prevention And Control
U.S. Code > Title 42 > Chapter 97 - Acid Precipitation Program And Carbon Dioxide Study
U.S. Code Title 42 > Chapter 134 > Subchapter XIII - Clean Air Coal Program

State Laws: Air Pollution

AlaskaAlaska Statutes Chapter 46.14 - Air Quality Control
ArizonaArizona Laws > Title 49 > Chapter 3 - Air Quality
CaliforniaCalifornia Health and Safety Code > Division 26 - Air Resources
California Public Utilities Code > Division 4.1 > Chapter 3.5 - Air Pollution Performance Standard For New Generatio
ConnecticutConnecticut General Statutes > Title 22a > Chapter 446b - Mid-Atlantic States Air Pollution Control Compact
Connecticut General Statutes > Title 22a > Chapter 446c - Air Pollution Control
FloridaFlorida Regulations Chapter 62-204 - Air Pollution Control - General Provisions
Florida Regulations Chapter 62-213 - Operation Permits for Major Sources of Air Pollution
Florida Regulations Chapter 62-214 - Requirements for Sources Subject To the Federal Acid Rain Program
Florida Regulations Chapter 62-252 - Gasoline Vapor Control
Florida Regulations Chapter 62-256 - Open Burning
HawaiiHawaii Revised Statutes Chapter 342B - Air Pollution Control
IdahoIdaho Code Title 39 > Chapter 67 - Treasure Valley And Regional Air Quality Council Act
IllinoisIllinois Compiled Statutes > 415 ILCS 130 - Interstate Ozone Transport Oversight Act
IndianaIndiana Code > Title 13 > Article 17 - Air Pollution Control
LouisianaLouisiana Revised Statutes > Title 30 > Chapter 3 - Louisiana Air Control Law
MaineMaine Revised Statutes > Title 38 > Chapter 4 - Protection And Improvement Of Air
MichiganMichigan Laws > Chapter 336
MissouriMissouri Laws > Title XL > Chapter 643 - Air Conservation
MontanaMontana Code Title 75 > Chapter 2 - Air Quality
NevadaNevada Revised Statutes > Chapter 445B - Air Pollution
New MexicoNew Mexico Statutes Chapter 74 > Article 2 - Air Pollution
New Mexico Statutes Chapter 74 > Article 2A - Wood Burning Stoves and Fireplaces
New YorkNew York Laws - Environmental Conservation > Article 19 - Air Pollution Control
New York Environmental Conservation Law > Article 51 > Title 5 - Air Quality Improvement Projects
New York Environmental Conservation Law > Article 56 > Title 6 - Air Quality Projects
New York Environmental Conservation Law > Article 72 > Title 3 - Air Quality Control Program Fee
New York Laws - Public Health > Article 12 - Task Force On Health Effects of Toll Plaza Air Quality In New York City
New YorkNew York Laws > Environmental Conservation > Article 19 - Air Pollution Control
New York Laws > Environmental Conservation > Article 51 > Title 5 - Air Quality Improvement Projects
New York Laws > Environmental Conservation > Article 56 > Title 6 - Air Quality Projects
New York Laws > Environmental Conservation > Article 72 > Title 3 - Air Quality Control Program Fee
New York Laws > Public Health > Article 12 - Task Force On Health Effects Of Toll Plaza Air Quality In New York City
North CarolinaNorth Carolina General Statutes Chapter 143 > Article 21B - Air Pollution Control
North DakotaNorth Dakota Code > Chapter 23-25 - Air Pollution Control
OhioOhio Code > Title 37 > Chapter 3704 - Air Pollution Control
Ohio Code > Title 37 > Chapter 3706 - Air Quality Development Authority
OregonOregon Statutes > Chapter 468A - Air Quality
Rhode IslandRhode Island General Laws > Chapter 1-7. The Permanent Air Quality Monitoring Act
Rhode Island General Laws > Chapter 23-23. Air Pollution
Rhode Island General Laws > Chapter 23-23.1. Air Pollution Episode Control
Rhode Island General Laws > Chapter 23-23.5. Noxious Trades
Rhode Island General Laws > Chapter 23-23.6. Air Quality in Ice Arenas
Rhode Island General Laws > Chapter 31-47.1. Motor Vehicle Emissions Inspection Program
Rhode Island General Laws > Chapter 31-47.2. Heavy Duty Diesel Vehicle Emission Inspections
Rhode Island General Laws > Chapter 31-47.3. The Diesel Emissions Reduction Act
South CarolinaSouth Carolina Code > Title 56 > Chapter 35 - Idling Restrictions For Commercial Diesel Vehicles
South DakotaSouth Dakota Laws > Title 34A > Chapter 1 - Air Pollution Control
TennesseeTennessee Code Title 68 > Environmental Protecion > Chapter 201 - Air Pollution Control
TexasTexas Health And Safety Code > Title 5 > Subtitle C - Air Quality
UtahUtah Code > Title 19 > Chapter 2 - Air Conservation Act
VermontVermont Statutes > Title 10 > Chapter 23 - Air Pollution Control
VirginiaVirginia Code Title 10.1 > Chapter 13 - Air Pollution Control Board
West VirginiaWest Virginia Code > Chapter 22 > Article 5 - Air Pollution Control
West Virginia Code > Chapter 22B > Article 2 - Air Quality Board
WisconsinWisconsin Statutes Chapter 285 - Air pollution

Comments (0)add comment

Post a comment or question below.
smaller | bigger

busy
 
Email  Email Print  Print   Digg

monotone-frail