Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

(a) Sulfuric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0005260.000175
Zinc0.0007010.000234

(2) Bar, billet and bloom.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0001690.0000563
Zinc0.0002250.0000751

(3) Strip, sheet and plate.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0003380.000113
Zinc0.0004510.000150

(4) Pipe, tube and other products.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0009390.000313
Zinc0.001250.000417

(5) Fume scrubbers.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kilograms per day
Lead0.03680.0123
Zinc0.04910.0164
The above limitations shall be applicable to each fume scrubber associated with a sulfuric acid pickling operation.

(b) Hydrochloric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0009200.000307
Zinc0.001230.000409

(2) Strip, sheet and plate.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0005260.000175
Zinc0.0007010.000234

(3) Pipe, tube and other products.

Subpart I

Pollutant or pollutant propertyBAT effuent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.001920.000638
Zinc0.002550.000851

(4) Fume scrubbers.

Subpart I

Pollutant or pollutant propertyBAT effuent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kilograms per day
Lead0.03680.0123
Zinc0.04910.0164
The above limitations shall be applicable to each fume scrubber associated with a hydrochloric acid pickling operation.

(5) Acid regeneration (absorber vent scrubber).

Subpart I

Pollutant or pollutant propertyBAT effuent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kilograms per day
Lead0.2450.0819
Zinc0.3270.109
The above limitations shall be applicable to the absorber vent scrubber wastewater associated with hydrochloric acid regeneration plants.

(c) Combination acid pickling (spent acid solution and rinse waters)—(1) Rod, wire, and coil.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.002130.000852
Nickel0.001920.000638

(2) Bar, billet, and bloom.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.0009600.000384
Nickel0.0008640.000288

(3) Strip, sheet, and plate—continuous.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.006260.00250
Nickel0.005630.00188

(4) Strip, sheet, and plate—batch.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.001920.000768
Nickel0.001730.000576

(5) Pipe, tube, and other products.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.003220.00129
Nickel0.002890.000964

(6) Fume scrubbers.

Subpart I

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kilograms per day
Chromium0.08190.0327
Nickel0.07350.0245
The above limitations shall be applicable to each fume scrubber associated with a combination acid pickling operation.[47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982, as amended at 49 FR 21031, May 17, 1984; 49 FR 24726, June 15, 1984]