(a) Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.

Subpart A—PSES

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Milligrams per liter (mg/l)
Chromium0.420.17
Lead0.150.13
Nickel1.411.00
Zinc1.330.56

(b) In cases where POTW find it necessary to impose mass effluent pretreatment standards the following equivalent mass standards are provided:

Subpart A—PSES

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Metal preparationCoating operationMetal preparationCoating operation
Metric units—mg/m 2 of area processed or coated
Chromium16.820.536.810.22
Lead6.010.195.210.16
Nickel56.51.7840.11.26
Zinc53.31.6822.50.71
English units—lbs/1 million ft 2 of area processed or coated
Chromium3.450.111.40.05
Lead1.230.041.070.03
Nickel11.60.378.200.26
Zinc10.90.354.60.15
[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36543, Sept. 6, 1985]