(a) Every person who digs, bores, or drills a water well, cathodic protection well, groundwater monitoring well, or geothermal heat exchange well, abandons or destroys such a well, or deepens or reperforates such a well, shall file with the department a report of completion of that well within 60 days from the date its construction, alteration, abandonment, or destruction is completed.

(b) The report shall be made on forms furnished by the department and shall contain information as follows:

Terms Used In California Water Code 13751

  • Cathodic protection well: as used in this chapter , means any artificial excavation in excess of 50 feet constructed by any method for the purpose of installing equipment or facilities for the protection electrically of metallic equipment in contact with the ground, commonly referred to as cathodic protection. See California Water Code 13711
  • Geothermal heat exchange well: as used in this chapter , means any uncased artificial excavation, by any method, that uses the heat exchange capacity of the earth for heating and cooling, in which excavation the ambient ground temperature is 30 degrees Celsius (86 degrees Fahrenheit) or less, and which excavation uses a closed loop fluid system to prevent the discharge or escape of its fluid into surrounding aquifers or other geologic formations. See California Water Code 13713
  • Monitoring well: as used in this chapter , means any artificial excavation by any method for the purpose of monitoring fluctuations in groundwater levels, quality of underground waters, or the concentration of contaminants in underground waters. See California Water Code 13712
  • Person: includes any city, county, district, the state, and the United States, to the extent authorized by federal law. See California Water Code 13050
  • water well: as used in this chapter , means any artificial excavation constructed by any method for the purpose of extracting water from, or injecting water into, the underground. See California Water Code 13710

(1) In the case of a water well, cathodic protection well, or groundwater monitoring well, the report shall contain information as required by the department, including, but not limited to all of the following information:

(A) A description of the well site sufficiently exact to permit location and identification of the well.

(B) A detailed log of the well.

(C) A description of type of construction.

(D) The details of perforation.

(E) The methods used for sealing off surface or contaminated waters.

(F) The methods used for preventing contaminated waters of one aquifer from mixing with the waters of another aquifer.

(G) The signature of the well driller.

(2) In the case of a geothermal heat exchange well, the report shall contain all of the following information:

(A) A description of the site that is sufficiently exact to permit the location and identification of the site and the number of geothermal heat exchange wells drilled on the same lot.

(B) A description of borehole diameter and depth and the type of geothermal heat exchange system installed.

(C) The methods and materials used to seal off surface or contaminated waters.

(D) The methods used for preventing contaminated water in one aquifer from mixing with the water in another aquifer.

(E) The signature of the well driller.

(Amended by Stats. 1996, Ch. 581, Sec. 6. Effective January 1, 1997.)