(1) Each licensee or registrant shall use the SI unit becquerel, gray, sievert and coulomb per kilogram, or the special units curie, rad, rem and roentgen, including multiples and subdivisions, and shall clearly indicate the units of all quantities on records required by this part. The information on shipping manifests, specified in subsection 64E-5.332(2), F.A.C., shall be recorded in SI units or in SI units and special units curie, rad, rem and roentgen.
    (2) The licensee or registrant shall make a clear distinction among the quantities entered on the records required by this part, such as total effective dose equivalent, shallow dose equivalent, lens dose equivalent, deep dose equivalent, or committed effective dose equivalent.
Rulemaking Authority 404.051, 404.081 FS. Law Implemented 404.051(1), (4), 404.081 FS. History-New 1-1-94, Formerly 10D-91.469, Amended 5-18-98, 10-8-00.