40 CFR 443.13 – Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable
Current as of: 2024 | Check for updates
|
Other versions
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (kg/cu m of runoff) | ||
TSS | 0.023 | 0.015 |
Oil and grease | 0.015 | 0.010 |
pH | (1) | (1) |
English units (lb/1,000 gal of runoff) | ||
TSS | 0.188 | 0.125 |
Oil and grease | 0.125 | 0.083 |
pH | (1) | (1) |
1 Within the range 6.0 to 9.0.