Effective 7/1/2023

15A-3-105.  Amendments to Chapters 10 through 12 of IBC.

(1)  In IBC, Section 1011.5.2, exception 3 is deleted and replaced with the following: ” 3. In Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum winder tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1 mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 10 inches (254 mm).”

(2)  In IBC, Section 1011.11, a new exception 6 is added as follows: ” 6. In occupancies in Group R-3, as applicable in Section 101.2 and in occupancies in Group U, which are accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails shall be provided on at least one side of stairways consisting of four or more risers.”

(3)  IBC, Section 1025, is deleted.

Amended by Chapter 209, 2023 General Session